{"id":14109,"date":"2026-03-05T13:16:58","date_gmt":"2026-03-05T11:16:58","guid":{"rendered":"https:\/\/schaefer-scientific.com\/?p=14109"},"modified":"2026-03-05T16:20:57","modified_gmt":"2026-03-05T14:20:57","slug":"rhk-panscan-freedom-ii-kryogenfreie-tieftemperatur-spm","status":"publish","type":"post","link":"https:\/\/schaefer-scientific.com\/de\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm","title":{"rendered":"Einf\u00fchrung des RHK PanScan Freedom II: Ein neuer Ma\u00dfstab f\u00fcr kryogenfreie Niedertemperatur-STM und AFM"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Schaefer Scientific stellt das RHK PanScan Freedom II vor, ein kryogenfreies Rastersondenmikroskopiesystem (SPM) der n\u00e4chsten Generation, das f\u00fcr die fortgeschrittene Forschung in den Bereichen Quantenmaterialien, Nanowissenschaften und Oberfl\u00e4chenwissenschaften entwickelt wurde.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Der PanScan Freedom II setzt einen neuen Standard f\u00fcr STM- und AFM-Experimente bei niedrigen Temperaturen, indem er den Betrieb bei extrem niedrigen Temperaturen, hohe Magnetfeldf\u00e4higkeit und au\u00dfergew\u00f6hnliche optische Zug\u00e4nglichkeit in einer einzigen kryogenen UHV-AFM\/STM-Plattform kombiniert. Dieses innovative System erm\u00f6glicht es Forschern, eine experimentelle Leistung auf Heliumniveau zu erreichen, ohne die mit Fl\u00fcssighelium-Kryostaten verbundenen betrieblichen Herausforderungen.<\/p>\n\n\n\n<div style=\"height:16px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Kryogenfreie Niedertemperatur-SPM-Leistung<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Das Herzst\u00fcck des PanScan Freedom II ist eine hochstabile, kryogenfreie Tieftemperatur-SPM-Plattform, die Basistemperaturen von bis zu 5 K erreichen kann. Das System enth\u00e4lt einen kryogenfreien supraleitenden 7-Tesla-Magneten, der magnetfeldabh\u00e4ngige Experimente ohne Unterbrechungen durch Helium-Nachf\u00fcllungen erm\u00f6glicht.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr Labore, die Quantenmaterialien, korrelierte Elektronensysteme und elektronische Ph\u00e4nomene im Nanobereich untersuchen, bietet dieser Ansatz die experimentelle Leistung herk\u00f6mmlicher kryogener Systeme und vereinfacht gleichzeitig den Laborbetrieb erheblich.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"269\" height=\"350\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/EquipmentImage_1269.webp\" alt=\"\" class=\"wp-image-14113\" style=\"aspect-ratio:1;object-fit:contain\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/EquipmentImage_1269.webp 269w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/EquipmentImage_1269-231x300.webp 231w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/EquipmentImage_1269-9x12.webp 9w\" sizes=\"(max-width: 269px) 100vw, 269px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:16px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Optischer Zugang f\u00fcr fortgeschrittene Experimente im Nanobereich<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ein entscheidendes Merkmal des PanScan Freedom II ist sein ungehinderter optischer Zugang innerhalb der Magnetumgebung. Dieses einzigartige Design erm\u00f6glicht es Forschern, die Rastersondenmikroskopie mit optischen Spektroskopietechniken zu kombinieren.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mit dem optionalen hocheffizienten optischen System Lumin bietet die Plattform:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mehr als 70% Lichtsammelwirkung<\/li>\n\n\n\n<li>Optischer Breitbandzugang vom Fern-IR bis zum Tief-UV<\/li>\n\n\n\n<li>Kompatibilit\u00e4t mit Raman-Spektroskopie, Photolumineszenz (PL), STM-induzierter Lumineszenz und Kathodolumineszenz<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Diese F\u00e4higkeiten machen das System zu einem idealen Werkzeug f\u00fcr die Untersuchung von Licht-Materie-Wechselwirkungen und optisch aktiven Nanostrukturen auf der Nanoskala.<\/p>\n\n\n\n<div style=\"height:16px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Flexible UHV AFM- und STM-Messungen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der PanScan Freedom II unterst\u00fctzt sowohl den Sondenscan- als auch den Probenscan-Modus, so dass Forscher das System an unterschiedliche experimentelle Anforderungen anpassen k\u00f6nnen. Das Sonden-Scanning erm\u00f6glicht ultrahochaufl\u00f6sende STM- und AFM-Messungen, w\u00e4hrend das optionale Proben-Scanning-Modul gr\u00f6\u00dfere Scanbereiche erm\u00f6glicht und dabei die pr\u00e4zise Ausrichtung der Sonde und den optischen Zugang aufrechterh\u00e4lt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Vielseitigkeit macht das System zu einer leistungsstarken L\u00f6sung f\u00fcr UHV-Rastersondenmikroskopie-Experimente bei kryogenen Temperaturen.<\/p>\n\n\n\n<div style=\"height:16px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Anwendungen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der PanScan Freedom II wurde f\u00fcr fortgeschrittene Forschungsbereiche entwickelt:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Quantenmaterialien und korrelierte Elektronensysteme<\/strong><\/li>\n\n\n\n<li><strong>STM- und AFM-Experimente bei niedriger Temperatur<\/strong><\/li>\n\n\n\n<li><strong>UHV Oberfl\u00e4chenwissenschaft<\/strong><\/li>\n\n\n\n<li><strong>Optisch aktive Nanostrukturen<\/strong><\/li>\n\n\n\n<li><strong>Studien zur Licht-Materie-Wechselwirkung<\/strong><\/li>\n\n\n\n<li><strong>Magnetfeldabh\u00e4ngige Spektroskopie auf der Nanoskala<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:16px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Erfahren Sie mehr \u00fcber UHV Cryogenic AFM\/STM Systeme<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Mehr Informationen \u00fcber <strong>Kryogene UHV-AFM- und STM-Scank\u00f6pfe und -Systeme<\/strong>&nbsp;die bei Schaefer Scientific erh\u00e4ltlich sind, finden Sie hier: <a href=\"https:\/\/schaefer-scientific.com\/de\/produkt\/uhv-kryogene-afm-stm-scan-kopfe-und-systeme\/\"><strong>https:\/\/schaefer-scientific.com\/product\/uhv-cryogenic-afm-stm-scan-heads-and-systems<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Forscher, die an einer Diskussion \u00fcber experimentelle Anforderungen oder Systemkonfigurationen interessiert sind, k\u00f6nnen sich gerne an das Team von Schaefer Scientific wenden.<\/p>","protected":false},"excerpt":{"rendered":"<p>Schaefer Scientific is pleased to announce the RHK PanScan Freedom II, a next-generation cryogen-free scanning probe microscopy (SPM) system&nbsp;designed for advanced research in quantum materials, nanoscience, and surface science. The PanScan Freedom II sets a new standard for low-temperature STM and AFM experiments&nbsp;by combining ultra-low temperature operation, high magnetic field capability, and exceptional optical accessibility [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":14114,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[69],"tags":[86],"class_list":["post-14109","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-panscan"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Cryogen-Free Low-Temperature STM &amp; AFM - RHK PanScan Freedom - Schaefer Scientific<\/title>\n<meta name=\"description\" content=\"Discover the RHK PanScan Freedom II: a cryogen-free low-temperature STM\/AFM system with 5 K base temperature and 7 T magnet for advanced quantum materials research.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/schaefer-scientific.com\/de\/nachrichten\/rhk-panscan-freedom-ii-kryogenfreie-tieftemperatur-spm\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cryogen-Free Low-Temperature STM &amp; AFM - RHK PanScan Freedom - Schaefer Scientific\" \/>\n<meta property=\"og:description\" content=\"Discover the RHK PanScan Freedom II: a cryogen-free low-temperature STM\/AFM system with 5 K base temperature and 7 T magnet for advanced quantum materials research.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/schaefer-scientific.com\/de\/nachrichten\/rhk-panscan-freedom-ii-kryogenfreie-tieftemperatur-spm\/\" \/>\n<meta property=\"og:site_name\" content=\"Schaefer Scientific\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-05T11:16:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-05T14:20:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/PanscanTestimonial-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"533\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"jensbonnier\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschrieben von\" \/>\n\t<meta name=\"twitter:data1\" content=\"jensbonnier\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"3\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm\"},\"author\":{\"name\":\"jensbonnier\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#\\\/schema\\\/person\\\/7c7118f14af6debc704d829b25555bf0\"},\"headline\":\"Introducing the RHK PanScan Freedom II: A New Benchmark in Cryogen-Free Low-Temperature STM and AFM\",\"datePublished\":\"2026-03-05T11:16:58+00:00\",\"dateModified\":\"2026-03-05T14:20:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm\"},\"wordCount\":425,\"publisher\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/PanscanTestimonial-1.jpg\",\"keywords\":[\"PanScan\"],\"articleSection\":[\"News\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm\",\"name\":\"Cryogen-Free Low-Temperature STM & AFM - RHK PanScan Freedom - Schaefer Scientific\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/PanscanTestimonial-1.jpg\",\"datePublished\":\"2026-03-05T11:16:58+00:00\",\"dateModified\":\"2026-03-05T14:20:57+00:00\",\"description\":\"Discover the RHK PanScan Freedom II: a cryogen-free low-temperature STM\\\/AFM system with 5 K base temperature and 7 T magnet for advanced quantum materials research.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#primaryimage\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/PanscanTestimonial-1.jpg\",\"contentUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/PanscanTestimonial-1.jpg\",\"width\":800,\"height\":533},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/news\\\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/schaefer-scientific.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Introducing the RHK PanScan Freedom II: A New Benchmark in Cryogen-Free Low-Temperature STM and AFM\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#website\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/\",\"name\":\"Schaefer Scientific\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/schaefer-scientific.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#organization\",\"name\":\"Schaefer Scientific\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Schaefer-Scientific-logo.webp\",\"contentUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Schaefer-Scientific-logo.webp\",\"width\":1177,\"height\":97,\"caption\":\"Schaefer Scientific\"},\"image\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#\\\/schema\\\/person\\\/7c7118f14af6debc704d829b25555bf0\",\"name\":\"jensbonnier\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c3e47f689a76469da09636b35d030ec2812801e40e412a815ace43613907229c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c3e47f689a76469da09636b35d030ec2812801e40e412a815ace43613907229c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c3e47f689a76469da09636b35d030ec2812801e40e412a815ace43613907229c?s=96&d=mm&r=g\",\"caption\":\"jensbonnier\"},\"sameAs\":[\"https:\\\/\\\/schaefer-scientific.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Kryogenfreies Niedertemperatur-STM &amp; AFM - RHK PanScan Freedom - Schaefer Scientific","description":"Entdecken Sie das RHK PanScan Freedom II: ein kryogenfreies Tieftemperatur-STM\/AFM-System mit 5 K Basistemperatur und 7 T Magnet f\u00fcr die Forschung an Quantenmaterialien.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/schaefer-scientific.com\/de\/nachrichten\/rhk-panscan-freedom-ii-kryogenfreie-tieftemperatur-spm\/","og_locale":"de_DE","og_type":"article","og_title":"Cryogen-Free Low-Temperature STM & AFM - RHK PanScan Freedom - Schaefer Scientific","og_description":"Discover the RHK PanScan Freedom II: a cryogen-free low-temperature STM\/AFM system with 5 K base temperature and 7 T magnet for advanced quantum materials research.","og_url":"https:\/\/schaefer-scientific.com\/de\/nachrichten\/rhk-panscan-freedom-ii-kryogenfreie-tieftemperatur-spm\/","og_site_name":"Schaefer Scientific","article_published_time":"2026-03-05T11:16:58+00:00","article_modified_time":"2026-03-05T14:20:57+00:00","og_image":[{"width":800,"height":533,"url":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/PanscanTestimonial-1.jpg","type":"image\/jpeg"}],"author":"jensbonnier","twitter_card":"summary_large_image","twitter_misc":{"Geschrieben von":"jensbonnier","Gesch\u00e4tzte Lesezeit":"3\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#article","isPartOf":{"@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm"},"author":{"name":"jensbonnier","@id":"https:\/\/schaefer-scientific.com\/#\/schema\/person\/7c7118f14af6debc704d829b25555bf0"},"headline":"Introducing the RHK PanScan Freedom II: A New Benchmark in Cryogen-Free Low-Temperature STM and AFM","datePublished":"2026-03-05T11:16:58+00:00","dateModified":"2026-03-05T14:20:57+00:00","mainEntityOfPage":{"@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm"},"wordCount":425,"publisher":{"@id":"https:\/\/schaefer-scientific.com\/#organization"},"image":{"@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#primaryimage"},"thumbnailUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/PanscanTestimonial-1.jpg","keywords":["PanScan"],"articleSection":["News"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm","url":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm","name":"Kryogenfreies Niedertemperatur-STM &amp; AFM - RHK PanScan Freedom - Schaefer Scientific","isPartOf":{"@id":"https:\/\/schaefer-scientific.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#primaryimage"},"image":{"@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#primaryimage"},"thumbnailUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/PanscanTestimonial-1.jpg","datePublished":"2026-03-05T11:16:58+00:00","dateModified":"2026-03-05T14:20:57+00:00","description":"Entdecken Sie das RHK PanScan Freedom II: ein kryogenfreies Tieftemperatur-STM\/AFM-System mit 5 K Basistemperatur und 7 T Magnet f\u00fcr die Forschung an Quantenmaterialien.","breadcrumb":{"@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#primaryimage","url":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/PanscanTestimonial-1.jpg","contentUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2026\/03\/PanscanTestimonial-1.jpg","width":800,"height":533},{"@type":"BreadcrumbList","@id":"https:\/\/schaefer-scientific.com\/news\/rhk-panscan-freedom-ii-cryogen-free-low-temperature-spm#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/schaefer-scientific.com\/"},{"@type":"ListItem","position":2,"name":"Introducing the RHK PanScan Freedom II: A New Benchmark in Cryogen-Free Low-Temperature STM and AFM"}]},{"@type":"WebSite","@id":"https:\/\/schaefer-scientific.com\/#website","url":"https:\/\/schaefer-scientific.com\/","name":"Schaefer Scientific","description":"","publisher":{"@id":"https:\/\/schaefer-scientific.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/schaefer-scientific.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/schaefer-scientific.com\/#organization","name":"Schaefer Scientific","url":"https:\/\/schaefer-scientific.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/schaefer-scientific.com\/#\/schema\/logo\/image\/","url":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/06\/Schaefer-Scientific-logo.webp","contentUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/06\/Schaefer-Scientific-logo.webp","width":1177,"height":97,"caption":"Schaefer Scientific"},"image":{"@id":"https:\/\/schaefer-scientific.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/schaefer-scientific.com\/#\/schema\/person\/7c7118f14af6debc704d829b25555bf0","name":"jensbonnier","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/c3e47f689a76469da09636b35d030ec2812801e40e412a815ace43613907229c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c3e47f689a76469da09636b35d030ec2812801e40e412a815ace43613907229c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c3e47f689a76469da09636b35d030ec2812801e40e412a815ace43613907229c?s=96&d=mm&r=g","caption":"jensbonnier"},"sameAs":["https:\/\/schaefer-scientific.com"]}]}},"_links":{"self":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/posts\/14109","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/comments?post=14109"}],"version-history":[{"count":6,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/posts\/14109\/revisions"}],"predecessor-version":[{"id":14119,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/posts\/14109\/revisions\/14119"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/media\/14114"}],"wp:attachment":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/media?parent=14109"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/categories?post=14109"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/tags?post=14109"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}