{"id":1058,"date":"2025-07-17T14:47:10","date_gmt":"2025-07-17T12:47:10","guid":{"rendered":"https:\/\/schaefer-scientific.com\/?post_type=product&#038;p=1058"},"modified":"2025-07-31T11:00:15","modified_gmt":"2025-07-31T09:00:15","slug":"thermische-massendurchflussmesser-und-regler","status":"publish","type":"product","link":"https:\/\/schaefer-scientific.com\/de\/product\/thermal-mass-flow-meters-controllers","title":{"rendered":"Thermische Massendurchflussmesser und -regler"},"content":{"rendered":"<div class=\"wp-block-columns block_text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Massendurchflussmesser und -regler<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Teledyne Hastings Instruments verf\u00fcgt \u00fcber mehr als 70 Jahre Erfahrung im Bereich der thermischen Massedurchflussmessung und -regelung und bietet eine umfassende Produktpalette an. Mit einem erfahrenen Entwicklungsteam, Fachwissen im Bereich der thermischen Massendurchflussmessung und einem weltweiten Vertriebs- und Servicenetz bietet Teledyne Hastings Instruments sowohl eine gro\u00dfe Auswahl an Ger\u00e4ten als auch einen un\u00fcbertroffenen Kundensupport.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hier finden Sie zuverl\u00e4ssige L\u00f6sungen f\u00fcr Ihre Anwendungen in Labor- und Industrieumgebungen, f\u00fcr hohe und niedrige Durchfl\u00fcsse, korrosive Gase und hohe Dr\u00fccke.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Produktlinie der Gasmassendurchflussmesser (HFM) und -regler (HFC) deckt einen breiten Bereich von Durchflussmengen von 5 sccm bis 15.000 slm ab und bietet eine Vielzahl flexibler Optionen f\u00fcr Ausg\u00e4nge, Kalibrierung und Anschl\u00fcsse.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Niedriger Durchfluss<br>(0-5 sccm bis 0-25 slm)<\/strong><\/th><th><strong>Mittlerer Durchfluss<br>(0-25 slm bis 0-1000 slm)<\/strong><\/th><th><strong>Hoher Durchfluss<br>(0-1000 slm bis 0-15.000 slm)<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Serie 300 Vue<br><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-188_rev-0218_Digital-300-Vue-Low-Flow.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-D-300B \/ HFC-D-302B<\/a><\/td><td>Serie 300 Vue<br><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-189_rev-018_Digital-300-Vue-Medium-Flow.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-D-301B \/ HFC-D-303B<\/a><\/td><td>Serie 300 Vue<br><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-189_rev-018_Digital-300-Vue-Medium-Flow.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-D-305B \/ HFC-D-307B<\/a><\/td><\/tr><tr><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-188_rev-0218_Digital-300-Vue-Low-Flow.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-D-300A \/ HFC-D-302A<\/a><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-189_rev-018_Digital-300-Vue-Medium-Flow.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-D-301A \/ HFC-D-303A<\/a><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-189_rev-018_Digital-300-Vue-Medium-Flow.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-D-305A \/ HFC-D-307A<\/a><\/td><\/tr><tr><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-140A_rev-1216_HFM-200_HFC-202.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-200 \/ HFC-202<\/a><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-140B_rev_1216_HFM-201_HFC-203.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-201 \/ HFC-203<\/a><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-187_rev-0218_Digital-300-Vue-High-Flow.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-D-306A\/B \/ HFC-D-308A\/B<\/a><\/td><\/tr><tr><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-150-rev-1005_HFM-300_HFC-302.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-300 \/ HFC-302<\/a><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-140C_rev-1017_HFM-200_Laminars.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-200 LFE<\/a><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-140C_rev-1017_HFM-200_Laminars.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-200 LFE<\/a><\/td><\/tr><tr><td><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-151-rev-1005_HFM-301_HFC-303.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-301 \/ HFC-303<\/a><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-184_rev-1017_HFM-205_HFC-207.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-205 \/ HFC-207<\/a><\/td><\/tr><tr><td><\/td><td><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-152-rev-1005_HFM-305_HFC-307.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-305 \/ HFC-307<\/a><\/td><\/tr><tr><td><\/td><td><\/td><td><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/PB-187_rev-0218_Digital-300-Vue-High-Flow.pdf\" rel=\"noreferrer noopener\" target=\"_blank\">HFM-306<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_image-text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Hauptmerkmale*<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Verf\u00fcgbare Durchflussbereiche<\/strong>\n<ul class=\"wp-block-list\">\n<li>Durchflussmesser: 0 - 5 sccm bis zu 0 - 15.000 slm (N2 Equiv)<\/li>\n\n\n\n<li>Durchflussregler: 0 - 5 sccm bis zu 0 - 10.000 slm (N2 Equiv)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Hohe Genauigkeit:<\/strong>\u00a0 von \u00b1(0,2% Skalenendwert + 0,5% des Messwerts)<\/li>\n\n\n\n<li><strong>Hohe Wiederholbarkeit:<\/strong>\u00a0 von \u00b10,05% vom Skalenendwert<\/li>\n\n\n\n<li><strong>Schnelle Einschwingzeiten<\/strong><\/li>\n\n\n\n<li><strong>Niedriger Druckverlust<\/strong><\/li>\n\n\n\n<li><strong>Metall- oder Elastomerdichtung<\/strong><\/li>\n\n\n\n<li><strong>Betriebsdr\u00fccke\u00a0<\/strong>bis zu 500 psi oder h\u00f6her (1000 psi optional)<\/li>\n\n\n\n<li><strong>Eingangsleistung:<\/strong>\u00a011-36 VDC unipolar oder bipolar (z. B. + 24 VDC, \u00b1 15 VDC)<\/li>\n\n\n\n<li><strong>Analoge Ausg\u00e4nge:<\/strong>\u00a00-5V, 0-10V, 0-20 mA, 4-20 mA<\/li>\n\n\n\n<li><strong>Sollwerteing\u00e4nge:<\/strong>\u00a00-5V, 0-10V, 0-20 mA, 4-20 mA<\/li>\n\n\n\n<li><strong>Digitale Schnittstellen:<\/strong>\u00a0RS232, RS485, USB<\/li>\n\n\n\n<li><strong>Verschiedene Armaturen:<\/strong>\u00a0Swagelok, VCR, VCO oder Flansch<\/li>\n\n\n\n<li><strong>NIST-r\u00fcckf\u00fchrbare Kalibrierung<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>*<\/strong>je nach Modellreihe<\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"617\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Family-e1535299353706-1024x617.webp\" alt=\"\" class=\"wp-image-1061\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Family-e1535299353706-1024x617.webp 1024w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Family-e1535299353706-300x181.webp 300w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Family-e1535299353706-768x463.webp 768w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Family-e1535299353706-1536x925.webp 1536w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Family-e1535299353706.webp 1995w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_image-text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">KDigital 300B Serie - 300 Vue<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Sehen Sie den Massenfluss auf eine ganz neue Art!<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Das 300 Vue ist die neueste Serie digitaler thermischer Gasmassendurchflussmessger\u00e4te, die eine genaue, schnelle und bequeme Gasmessung und -regelung erm\u00f6glichen.  Das Farb-Touchscreen-Display erm\u00f6glicht es dem Benutzer, die Durchflussrate direkt am Ger\u00e4t anzuzeigen und zu steuern. Auf dem Hauptbildschirm werden die Durchflussrate, der Durchflusssollwert (im Falle eines Reglers), die Ma\u00dfeinheiten und der Ventilmodus (Auto, Offen, Geschlossen) angezeigt. Auf dem Display k\u00f6nnen auch \u00c4nderungen des Durchflusses \u00fcber die Zeit grafisch dargestellt werden. Die B-Serie verf\u00fcgt au\u00dferdem \u00fcber einen USB-Anschluss, der bei allen Z\u00e4hlern und Reglern Standard ist. Das Ger\u00e4t kann innerhalb von Sekunden installiert und in Betrieb genommen werden.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Farb-Touchscreen-Display<\/li>\n\n\n\n<li>Ausgezeichnete Genauigkeit \u00b1 (0,5% Pt + 0,2% FS)<\/li>\n\n\n\n<li>Multigas-Kalibrierungen<\/li>\n\n\n\n<li>Sensor-Diagnose<\/li>\n\n\n\n<li>Z\u00e4hlwerk<\/li>\n\n\n\n<li>Analoger Ausgang: 0-5V, 0-10V, 0-20 mA, 4-20 mA<\/li>\n\n\n\n<li>Digitaler Ausgang: RS232, RS485, USB<\/li>\n\n\n\n<li>Durchflusskapazit\u00e4t von 5 sccm bis 10.000 slm<\/li>\n\n\n\n<li>Befestigungsm\u00f6glichkeiten von Kompression bis Oberfl\u00e4chenmontage<\/li>\n\n\n\n<li>Metall- und Elastomerdichtung verf\u00fcgbar<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"911\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Teledyne-Hastings-300-Vue-Touch-Screen-1024x911.webp\" alt=\"\" class=\"wp-image-1062\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Teledyne-Hastings-300-Vue-Touch-Screen-1024x911.webp 1024w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Teledyne-Hastings-300-Vue-Touch-Screen-300x267.webp 300w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Teledyne-Hastings-300-Vue-Touch-Screen-768x683.webp 768w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Teledyne-Hastings-300-Vue-Touch-Screen-1536x1366.webp 1536w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Teledyne-Hastings-300-Vue-Touch-Screen.webp 2000w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><strong>Hastings' beobachten\u00a0<a href=\"https:\/\/youtu.be\/07CLrY_t1mY\" target=\"_blank\" rel=\"noreferrer noopener\">Video<\/a>\u00a0\u00fcber den 300 Vue!<\/strong><\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_image-text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Serie 200<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Allgemeine Verwendung - Ausgezeichnete Stabilit\u00e4t!<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Serie 200, die flexible, universell einsetzbare Serie von Massendurchflussmessern und -reglern von Teledyne Hastings, misst und regelt den Massendurchfluss in einer Vielzahl von Anwendungen pr\u00e4zise. Die Serie 200 zeichnet sich durch Zuverl\u00e4ssigkeit und Stabilit\u00e4t aus und wird wegen ihrer sehr stabilen Leistung bei wechselnden Umgebungsbedingungen gew\u00e4hlt. Eine gro\u00dfe Auswahl an Elastomerdichtungen macht diesen Durchflussregler mit den meisten Gasen kompatibel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Der volle Skalenbereich wird vom Endbenutzer festgelegt. Ein NIST-r\u00fcckf\u00fchrbares Kalibrierungszertifikat ist Standard. Viele korrosive Gase und Dr\u00fccke bis zu 1000 psig lassen sich problemlos messen. Eine Reinigung f\u00fcr den Einsatz mit Sauerstoff ist verf\u00fcgbar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Geringer Druckverlust, gro\u00dfe Durchflussmengen!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die HFM-200 LFE-Serie von Teledyne Hastings kann f\u00fcr die genaue Messung des Gasdurchflusses in einem breiten Spektrum von Anwendungen konfiguriert werden. Das HFM-200 LFE-Messger\u00e4t hat Durchflussbereiche von 0-10 sccm bis 0-15.000 slm, bietet analoge Ausg\u00e4nge und ist aus Edelstahl gefertigt.  Die Laminar Flow Elemente (glatt, mit Gewinde oder Flansch) sind in verschiedenen Gr\u00f6\u00dfen von 3\/8\u2033 bis 8\u2033 erh\u00e4ltlich.  Geringe Druckabf\u00e4lle bei vollem Durchfluss.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"723\" height=\"600\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Controller-HFC-203.webp\" alt=\"\" class=\"wp-image-1063\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Controller-HFC-203.webp 723w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Controller-HFC-203-300x249.webp 300w\" sizes=\"(max-width: 723px) 100vw, 723px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"490\" height=\"490\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Meter-HFM-200-W-LFE.webp\" alt=\"\" class=\"wp-image-1065\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Meter-HFM-200-W-LFE.webp 490w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Meter-HFM-200-W-LFE-300x300.webp 300w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Flow-Meter-HFM-200-W-LFE-150x150.webp 150w\" sizes=\"(max-width: 490px) 100vw, 490px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_image-text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Serie 300<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ganz aus Metall, schnelle Reaktion, niedrige Durchflussraten!<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Serie 300 zeichnet sich durch Zuverl\u00e4ssigkeit und Stabilit\u00e4t aus und wird wegen ihres schnellen Ansprechens unter einer Vielzahl von Bedingungen gew\u00e4hlt. Die metallgedichteten HFM-300 \/ HFC-302 Mess- und Regelger\u00e4te haben Durchflussbereiche von 0-5 sccm bis zu Durchfl\u00fcssen von 0-25 slm. Sie sind f\u00fcr die genaue Messung des Massendurchflusses ohne Korrekturen oder Kompensationen f\u00fcr Gasdruck und Temperatur ausgelegt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Korrosive Gase und Dr\u00fccke bis zu 1000 psig werden problemlos gemessen. Bei moderaten \u00dcberdr\u00fccken oder \u00dcberstr\u00f6mungen treten keine Sch\u00e4den auf.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Hohe Leistung - schnelle Reaktion!<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Messger\u00e4te HFM-301\/-305\/-306 und die Steuerger\u00e4te HFC-303\/-307 zeichnen sich durch hervorragende Einschwingzeiten aus und decken den mittleren bis hohen Durchflussbereich ab. Der Messbereichsendwert wird vom Endbenutzer festgelegt. Die Ger\u00e4te verf\u00fcgen \u00fcber analoge Ausg\u00e4nge, sind aus rostfreiem Stahl gefertigt und k\u00f6nnen entweder mit normal offenen oder normal geschlossenen Ventilen konfiguriert werden. Diese Ger\u00e4te sind in sich linear und haben eine Genauigkeit von besser als \u00b11% F.S. (full scale).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hastings-Massendurchflussmessger\u00e4te erfordern unter normalen Betriebsbedingungen mit sauberen Gasen keine regelm\u00e4\u00dfige Wartung.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1445\" height=\"992\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-300_HFC-302.webp\" alt=\"\" class=\"wp-image-1067\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-300_HFC-302.webp 1445w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-300_HFC-302-300x206.webp 300w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-300_HFC-302-1024x703.webp 1024w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-300_HFC-302-768x527.webp 768w\" sizes=\"(max-width: 1445px) 100vw, 1445px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1426\" height=\"1010\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-305_HFC-307.webp\" alt=\"\" class=\"wp-image-1068\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-305_HFC-307.webp 1426w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-305_HFC-307-300x212.webp 300w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-305_HFC-307-1024x725.webp 1024w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFM-305_HFC-307-768x544.webp 768w\" sizes=\"(max-width: 1426px) 100vw, 1426px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_image-text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Serie Digital 300A<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ganz aus Metall, schnelle Reaktion, hohe Genauigkeit!<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Massedurchflussmessger\u00e4te HFM-D-300A \/ HFC-D-302A haben Durchflussbereiche von 0-5 sccm bis 0-25 slm, verwenden Ganzmetalldichtungen, bieten analoge und digitale Ausg\u00e4nge und haben eine Genauigkeit von besser als&nbsp;<strong>\u00b1<\/strong>(0,5% des Messwerts + 0,2% des Skalenendwerts) f\u00fcr Vollskalenraten. Einfache, benutzerfreundliche digitale Kommunikation mit Windows-basierter Software-Schnittstelle ist verf\u00fcgbar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Digital 300 Serie verwendet einen thermisch basierten Massendurchflusssensor, der f\u00fcr ein au\u00dfergew\u00f6hnlich lineares Ansprechen auf sich \u00e4ndernde Durchflussraten ausgelegt ist. Dar\u00fcber hinaus ist die mit jedem Sensor verbundene Elektronik genau abgestimmt, um eine schnelle Reaktionszeit zu gew\u00e4hrleisten. Der gro\u00dfe Durchmesser des Sensorrohrs erm\u00f6glicht dem Digital 300 Durchflussmesser einen geringen Druckabfall.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Digital verbessert, mit h\u00f6chster Genauigkeit!<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Messung eines Gasflusses mit einer massebasierten Messung bietet Genauigkeit, Wiederholbarkeit und Stabilit\u00e4t.  Die A-Serie der Digital 300 Reihe deckt Bereiche von 0-1000 slm (HFM-D-301A\/HFC-D-303A), 0-2500 slm (HFM-D-305A\/HFC-D-307A) bis 0-10.000 slm (HFM-D-306A\/HFC-D-308A) ab. Er kann mit einem optionalen IP-67-Geh\u00e4use konfiguriert werden, das Schutz vor Wasser und Staub bietet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Selbstdiagnose des Sensors, des Ventils und des \u00dcberlaufs ist in den digitalen Funktionen enthalten. Interessant ist auch die automatische Nullstellungsfunktion, die erkennt, wenn das Ventil geschlossen ist, und den Nullpunkt automatisch zur\u00fccksetzt. Diese Massendurchflussmesser und -regler k\u00f6nnen bis zu 10 Kalibrierungen f\u00fcr verschiedene Bereiche und Gase speichern.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Digital 300 Serie kann mit jeder Stromversorgung betrieben werden, die 11 - 36 VDC zwischen den High und Low Supply Pins liefert (z.B. bipolar \u00b112 VDC, \u00b115 VDC oder unipolar +24 VDC).<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2000\" height=\"2413\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-302A.webp\" alt=\"\" class=\"wp-image-1070\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-302A.webp 2000w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-302A-249x300.webp 249w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-302A-849x1024.webp 849w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-302A-768x927.webp 768w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-302A-1273x1536.webp 1273w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-302A-1697x2048.webp 1697w\" sizes=\"(max-width: 2000px) 100vw, 2000px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2000\" height=\"1195\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-308A.webp\" alt=\"\" class=\"wp-image-1071\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-308A.webp 2000w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-308A-300x179.webp 300w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-308A-1024x612.webp 1024w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-308A-768x459.webp 768w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-HFC-D-308A-1536x918.webp 1536w\" sizes=\"(max-width: 2000px) 100vw, 2000px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_image-text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Stromversorgung &amp; Display<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/181-THCD-101-Manual.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Einkanalige Stromversorgung \/ Display<\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Verarbeitet einen Durchflussmesser,<br>Controller oder Vakuummeter<\/li>\n\n\n\n<li>Anzeige der Ma\u00dfeinheiten<\/li>\n\n\n\n<li>Analog: 0-5 vdc, 0-10 vdc<\/li>\n\n\n\n<li>RS-232\/RS-485<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/schaefer-tec.com\/wp-content\/uploads\/183-THCD-401_Manual.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Vier-Kanal-Netzteil \/ Display<\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Arbeitet mit vier Durchflussmessern, Reglern,<br>Vakuummessger\u00e4te, und mehr<\/li>\n\n\n\n<li>Zeigt 4 gleichzeitige Kan\u00e4le an<br>mit Einheiten und Gas-ID<\/li>\n\n\n\n<li>Analog: 0-5 vdc, 0-10 vdc, 4-20 mA<\/li>\n\n\n\n<li>RS-232\/RS-485<\/li>\n\n\n\n<li>Mischungsverh\u00e4ltnisregelung f\u00fcr Gasgemische<\/li>\n\n\n\n<li>Totalisator-Funktion<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"728\" height=\"518\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/THCD-101.webp\" alt=\"\" class=\"wp-image-1073\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/THCD-101.webp 728w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/THCD-101-300x213.webp 300w\" sizes=\"(max-width: 728px) 100vw, 728px\" \/><figcaption class=\"wp-element-caption\"><strong>Teledyne Hastings Instruments THCD-101<\/strong><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"841\" height=\"526\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/THCD-401.webp\" alt=\"\" class=\"wp-image-1074\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/THCD-401.webp 841w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/THCD-401-300x188.webp 300w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/THCD-401-768x480.webp 768w\" sizes=\"(max-width: 841px) 100vw, 841px\" \/><figcaption class=\"wp-element-caption\"><strong>Teledyne Hastings Instruments THCD-401<\/strong><\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_image-text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Kostenlose Massendurchfluss-Konverter APP<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Teledyne Hastings Instruments hat eine APP zur Umrechnung von Massendurchfluss entwickelt, mit der sich Durchflussmesswerte schnell von einer Einheit in eine andere umrechnen lassen. Der Benutzer hat auch die M\u00f6glichkeit, die Gasspezies und die Referenzbedingungen oder STP (Standard Temperature &amp; Pressure) zu \u00e4ndern, die bei der Umrechnung zwischen Massendurchflusseinheiten wie gm\/s, lbs\/hr und abgeleiteten volumetrischen Einheiten wie slm, sccm, scfh, scfm usw. angegeben werden m\u00fcssen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Es sind vier Versionen verf\u00fcgbar: iPhone, iPad, Android und webbasiert. Die Versionen f\u00fcr iPhone und iPad k\u00f6nnen kostenlos aus dem Apple iTunes Store heruntergeladen werden. Die Version f\u00fcr Android kann \u00fcber Google Play bezogen werden. Die webbasierte Version ist verf\u00fcgbar unter&nbsp;<em><a href=\"http:\/\/www.massflowconverter.com\/\" target=\"_blank\" rel=\"noreferrer noopener\">www.massflowconverter.com<\/a><\/em>.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"450\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Mass-Flow-Converter-APP-1.webp\" alt=\"\" class=\"wp-image-1075\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Mass-Flow-Converter-APP-1.webp 600w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-Mass-Flow-Converter-APP-1-300x225.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Kalibrierung und Reparaturdienste<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Eine regelm\u00e4\u00dfige Kalibrierung von Messger\u00e4ten, die in der Prozesskontrolle oder bei Forschungsprojekten eingesetzt werden, wird dringend empfohlen!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5 Gr\u00fcnde f\u00fcr eine periodische Rekalibrierung:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Alterung \/ Stress<\/li>\n\n\n\n<li>Verunreinigung<\/li>\n\n\n\n<li>Toleranzverschiebungen<\/li>\n\n\n\n<li>Gleichbleibende Qualit\u00e4t des Endprodukts<\/li>\n\n\n\n<li>Geringere Prozessineffizienzen<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Hastings' Webinar-Aufzeichnung herunterladen \"<a href=\"http:\/\/info.teledyne-hi.com\/flow-calibration-webinar-recording?__hstc=150192105.714f09d6620fa83fcfb1d99ac28c7c6b.1528224632913.1530124338426.1530215899826.4&amp;__hssc=150192105.6.1530215899826&amp;__hsfp=3986264363\" target=\"_blank\" rel=\"noreferrer noopener\">Bew\u00e4hrte Praktiken der Durchflusskalibrierung<\/a>\" und erfahren Sie mehr \u00fcber die&nbsp;<a href=\"http:\/\/info.teledyne-hi.com\/blog\/mass-flow-controller-calibration-report-what-does-it-mean\" target=\"_blank\" rel=\"noreferrer noopener\">Kalibrierungsbericht<\/a>&nbsp;auf Hastings' Blog!<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Anwendungen und Branchen<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>Luftprobenahme<\/li>\n\n\n\n<li>Industrie\u00f6fen<\/li>\n\n\n\n<li>Gasmischung<\/li>\n\n\n\n<li>Medizinische Forschung<\/li>\n\n\n\n<li>Analytische Instrumentierung<\/li>\n\n\n\n<li>Charakterisierung von Katalysatoren<\/li>\n\n\n\n<li>Getr\u00e4nkeindustrie<\/li>\n\n\n\n<li>Gaschromatographie<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>Thermisches Flammenspray<\/li>\n\n\n\n<li>Dichtheitspr\u00fcfung<\/li>\n\n\n\n<li>Luft- und Raumfahrt<\/li>\n\n\n\n<li>Porosit\u00e4tsstudien<\/li>\n\n\n\n<li>D\u00fcnnschichtabscheidung<\/li>\n\n\n\n<li>Lieferung von hochreinem Gas<\/li>\n\n\n\n<li>Pharmazeutisches Verfahren<\/li>\n\n\n\n<li>Kfz-Pr\u00fcfung<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>\u00dcberwachung der Verschmutzung<\/li>\n\n\n\n<li>Halbleiter-Prozess<\/li>\n\n\n\n<li>Erneuerbare Energien<\/li>\n\n\n\n<li>Brennstoffzellen-F&amp;E<\/li>\n\n\n\n<li>\u00dcbertragung der Verwahrung<\/li>\n\n\n\n<li>Photovoltaischer Prozess<\/li>\n\n\n\n<li>Glasindustrie<\/li>\n\n\n\n<li>Plasma-Beschichtungsprozess<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"featured_media":1059,"template":"","meta":{"_acf_changed":false},"application":[33],"manufacturer":[34],"product-category":[26],"class_list":["post-1058","product","type-product","status-publish","has-post-thumbnail","hentry","application-thin-film-deposition","manufacturer-teledyne-hastings-instruments","product-category-measurement-and-control"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Thermal Mass Flow Meters &amp; Controllers - Schaefer Scientific<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/schaefer-scientific.com\/de\/produkt\/thermische-massendurchflussmesser-und-regler\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Thermal Mass Flow Meters &amp; Controllers - Schaefer Scientific\" \/>\n<meta property=\"og:description\" content=\"Mass Flow Meters &amp; Controllers Teledyne Hastings Instruments brings&nbsp;over 70 years of experience to offer a full line of thermal mass flow measurement and control instruments. With an experienced design team, thermal mass flow expertise, and global sales and service networks, Teledyne Hastings Instruments provides both a broad selection of equipment and unrivaled customer support. [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/schaefer-scientific.com\/de\/produkt\/thermische-massendurchflussmesser-und-regler\/\" \/>\n<meta property=\"og:site_name\" content=\"Schaefer Scientific\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-31T09:00:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-300-Vue-HFC-D-303B.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1788\" \/>\n\t<meta property=\"og:image:height\" content=\"1400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"9\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/thermal-mass-flow-meters-controllers\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/thermal-mass-flow-meters-controllers\",\"name\":\"Thermal Mass Flow Meters &amp; Controllers - Schaefer Scientific\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/thermal-mass-flow-meters-controllers#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/thermal-mass-flow-meters-controllers#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/Hastings-300-Vue-HFC-D-303B.webp\",\"datePublished\":\"2025-07-17T12:47:10+00:00\",\"dateModified\":\"2025-07-31T09:00:15+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/thermal-mass-flow-meters-controllers#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/thermal-mass-flow-meters-controllers\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/thermal-mass-flow-meters-controllers#primaryimage\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/Hastings-300-Vue-HFC-D-303B.webp\",\"contentUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/Hastings-300-Vue-HFC-D-303B.webp\",\"width\":1788,\"height\":1400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/thermal-mass-flow-meters-controllers#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/schaefer-scientific.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Thermal Mass Flow Meters &amp; Controllers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#website\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/\",\"name\":\"Schaefer Scientific\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/schaefer-scientific.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#organization\",\"name\":\"Schaefer Scientific\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Schaefer-Scientific-logo.webp\",\"contentUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Schaefer-Scientific-logo.webp\",\"width\":1177,\"height\":97,\"caption\":\"Schaefer Scientific\"},\"image\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Thermische Massedurchflussmesser und -regler - Schaefer Scientific","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/schaefer-scientific.com\/de\/produkt\/thermische-massendurchflussmesser-und-regler\/","og_locale":"de_DE","og_type":"article","og_title":"Thermal Mass Flow Meters &amp; Controllers - Schaefer Scientific","og_description":"Mass Flow Meters &amp; Controllers Teledyne Hastings Instruments brings&nbsp;over 70 years of experience to offer a full line of thermal mass flow measurement and control instruments. With an experienced design team, thermal mass flow expertise, and global sales and service networks, Teledyne Hastings Instruments provides both a broad selection of equipment and unrivaled customer support. [&hellip;]","og_url":"https:\/\/schaefer-scientific.com\/de\/produkt\/thermische-massendurchflussmesser-und-regler\/","og_site_name":"Schaefer Scientific","article_modified_time":"2025-07-31T09:00:15+00:00","og_image":[{"width":1788,"height":1400,"url":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-300-Vue-HFC-D-303B.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"9\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/schaefer-scientific.com\/product\/thermal-mass-flow-meters-controllers","url":"https:\/\/schaefer-scientific.com\/product\/thermal-mass-flow-meters-controllers","name":"Thermische Massedurchflussmesser und -regler - Schaefer Scientific","isPartOf":{"@id":"https:\/\/schaefer-scientific.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/schaefer-scientific.com\/product\/thermal-mass-flow-meters-controllers#primaryimage"},"image":{"@id":"https:\/\/schaefer-scientific.com\/product\/thermal-mass-flow-meters-controllers#primaryimage"},"thumbnailUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-300-Vue-HFC-D-303B.webp","datePublished":"2025-07-17T12:47:10+00:00","dateModified":"2025-07-31T09:00:15+00:00","breadcrumb":{"@id":"https:\/\/schaefer-scientific.com\/product\/thermal-mass-flow-meters-controllers#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/schaefer-scientific.com\/product\/thermal-mass-flow-meters-controllers"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/schaefer-scientific.com\/product\/thermal-mass-flow-meters-controllers#primaryimage","url":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-300-Vue-HFC-D-303B.webp","contentUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/Hastings-300-Vue-HFC-D-303B.webp","width":1788,"height":1400},{"@type":"BreadcrumbList","@id":"https:\/\/schaefer-scientific.com\/product\/thermal-mass-flow-meters-controllers#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/schaefer-scientific.com\/"},{"@type":"ListItem","position":2,"name":"Thermal Mass Flow Meters &amp; Controllers"}]},{"@type":"WebSite","@id":"https:\/\/schaefer-scientific.com\/#website","url":"https:\/\/schaefer-scientific.com\/","name":"Schaefer Scientific","description":"","publisher":{"@id":"https:\/\/schaefer-scientific.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/schaefer-scientific.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/schaefer-scientific.com\/#organization","name":"Schaefer Scientific","url":"https:\/\/schaefer-scientific.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/schaefer-scientific.com\/#\/schema\/logo\/image\/","url":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/06\/Schaefer-Scientific-logo.webp","contentUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/06\/Schaefer-Scientific-logo.webp","width":1177,"height":97,"caption":"Schaefer Scientific"},"image":{"@id":"https:\/\/schaefer-scientific.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/product\/1058","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/media\/1059"}],"wp:attachment":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/media?parent=1058"}],"wp:term":[{"taxonomy":"application","embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/application?post=1058"},{"taxonomy":"manufacturer","embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/manufacturer?post=1058"},{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/product-category?post=1058"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}