{"id":1192,"date":"2025-07-18T10:54:32","date_gmt":"2025-07-18T08:54:32","guid":{"rendered":"https:\/\/schaefer-scientific.com\/?post_type=product&#038;p=1192"},"modified":"2026-02-09T09:49:53","modified_gmt":"2026-02-09T07:49:53","slug":"kapazitatsbrucken","status":"publish","type":"product","link":"https:\/\/schaefer-scientific.com\/de\/product\/capacitance-bridges","title":{"rendered":"Kapazit\u00e4tsbr\u00fccken"},"content":{"rendered":"<div class=\"wp-block-columns block_text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Pr\u00e4zisions-Kapazit\u00e4tsmessbr\u00fccken<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Kapazit\u00e4tsmessbr\u00fccken des Herstellers Andeen-Hagerling bieten eine Kapazit\u00e4tsaufl\u00f6sung bis in den Sub-Attofarad-Bereich (10<sup>-18<\/sup>&nbsp;F!)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Messbr\u00fccken haben sich seit vielen Jahren in einem breiten Anwendungsspektrum bew\u00e4hrt und sind die Grundlage f\u00fcr entsprechende Ver\u00f6ffentlichungen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dielektrische Charakterisierung<\/li>\n\n\n\n<li>Quantenkapazit\u00e4ten<br>(Kohlenstoff-Nanor\u00f6hrchen, Nanodr\u00e4hte, Quantenpunkte, Graphen)<\/li>\n\n\n\n<li>Dilatometrie, thermische Ausdehnung, Magnetorestriktion<\/li>\n\n\n\n<li>Ferroelektrika, Multiferroika<\/li>\n\n\n\n<li>Fl\u00fcssigkristalle<\/li>\n\n\n\n<li>Physik bei niedrigen Temperaturen<\/li>\n\n\n\n<li>Magnetoresistive Effekte, magnetische Kapazit\u00e4t<\/li>\n\n\n\n<li>Magnetometrie<\/li>\n\n\n\n<li>Nanokraft-Erkennung\/Messtechnik<\/li>\n\n\n\n<li>\u00dcbergang Glas\/Glas-Fl\u00fcssigkeit<\/li>\n\n\n\n<li>Elektrische und kapazitive Messtechnik<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Allgemeine Spezifikationen<br>(Option-E: mit verbesserter Genauigkeit)<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Messbarer Verlustfaktor bis zu 1,5 \u00d7 10<sup>-8<\/sup>\u00a0tan(\u03b4), Leitf\u00e4higkeit 3 \u00d7 10<sup>-7<\/sup>\u00a0Nanosiemens - entspricht einem Widerstand von 1,7 \u00d7 10<sup>6\u00a0<\/sup>G\u03a9<\/li>\n\n\n\n<li>Analoger Ausgang (3 kHz bei 3 dB)<\/li>\n\n\n\n<li>Negative Verlust- und Kapazit\u00e4tsmessbereiche zur Messung ungew\u00f6hnlicher Proben oder 3-Pol-Netze<\/li>\n\n\n\n<li>Kommutierung (Invertierung des Pr\u00fcfsignals) zur Minimierung von externen Netzeinfl\u00fcssen oder anderen periodischen Aufnahmesignalen<\/li>\n\n\n\n<li>IEEE-GPIB und IEEE-1174 serielle Schnittstellen<\/li>\n\n\n\n<li>Programmierbar (erfordert m\u00f6glicherweise keine externe Steuerung)<\/li>\n\n\n\n<li>Abweichung - Messungen (Kapazit\u00e4t, Verlust - oder beides)<\/li>\n\n\n\n<li>Externe DC-Vorspannung bis zu +\/- 100 V<\/li>\n\n\n\n<li>Verf\u00fcgbare Referenz-Standardkapazit\u00e4ten - Modell<strong>\u00a0AH 1100<\/strong><\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_image-text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Multifrequenz<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Modelle<\/th><th>AH 2700A<br>(Option-E)<\/th><th>AH 2700A Option-C<br>(Option-E)<\/th><\/tr><\/thead><tbody><tr><td>Frequenzgang<\/td><td>50 Hz - 20 KHz<\/td><td>50 Hz - 20 KHz<\/td><\/tr><tr><td>Messfrequenzen<\/td><td>33 voreingestellte Frequenzen<\/td><td>kontinuierlich<\/td><\/tr><tr><td>Aufl\u00f6sung Kapazit\u00e4tswert<\/td><td>bis zu Sub aF<br>(atto Farad)<\/td><td>bis zu Sub aF<br>(atto Farad)<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"395\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs-1024x395.webp\" alt=\"\" class=\"wp-image-1193\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs-1024x395.webp 1024w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs-300x116.webp 300w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs-768x297.webp 768w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs.webp 1321w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns block_image-text is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Einzelne Frequenz<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Modell<\/th><th>AH 2550A<\/th><\/tr><\/thead><tbody><tr><td>Frequenzgang<\/td><td>1 KHz<\/td><\/tr><tr><td>Messfrequenzen<\/td><td>1 KHz<\/td><\/tr><tr><td>Kapazit\u00e4tsaufl\u00f6sung<\/td><td>bis Sub aF (atto Farad)<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"358\" src=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2550Aphoto-GOOD-LowRes-1024x358.webp\" alt=\"\" class=\"wp-image-1194\" srcset=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2550Aphoto-GOOD-LowRes-1024x358.webp 1024w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2550Aphoto-GOOD-LowRes-300x105.webp 300w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2550Aphoto-GOOD-LowRes-768x269.webp 768w, https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2550Aphoto-GOOD-LowRes.webp 1318w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>","protected":false},"featured_media":1193,"template":"","meta":{"_acf_changed":true},"application":[43],"manufacturer":[44],"product-category":[26],"class_list":["post-1192","product","type-product","status-publish","has-post-thumbnail","hentry","application-precision-capacitance-measurement","manufacturer-andeen-hagerling-inc","product-category-measurement-and-control"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Capacitance bridges - Schaefer Scientific<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/schaefer-scientific.com\/de\/produkt\/kapazitatsbrucken\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Capacitance bridges - Schaefer Scientific\" \/>\n<meta property=\"og:description\" content=\"Precision capacitance measuring bridges The capacitance measuring bridges from the manufacturer Andeen-Hagerling offer a capacitance resolution down to the sub-attofarad (10-18&nbsp;F!) These measuring bridges have proven themselves for many years in a wide range of applications and are the basis for corresponding publications: General Specifications(Option-E: with improved accuracy) Multi-frequency Models AH 2700A(Option-E) AH 2700A Option-C(Option-E) [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/schaefer-scientific.com\/de\/produkt\/kapazitatsbrucken\/\" \/>\n<meta property=\"og:site_name\" content=\"Schaefer Scientific\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-09T07:49:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1321\" \/>\n\t<meta property=\"og:image:height\" content=\"510\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"2\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/capacitance-bridges\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/capacitance-bridges\",\"name\":\"Capacitance bridges - Schaefer Scientific\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/capacitance-bridges#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/capacitance-bridges#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/2700Aphoto-GOOD-LowREs.webp\",\"datePublished\":\"2025-07-18T08:54:32+00:00\",\"dateModified\":\"2026-02-09T07:49:53+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/capacitance-bridges#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/capacitance-bridges\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/capacitance-bridges#primaryimage\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/2700Aphoto-GOOD-LowREs.webp\",\"contentUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/2700Aphoto-GOOD-LowREs.webp\",\"width\":1321,\"height\":510},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/product\\\/capacitance-bridges#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/schaefer-scientific.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Capacitance bridges\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#website\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/\",\"name\":\"Schaefer Scientific\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/schaefer-scientific.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#organization\",\"name\":\"Schaefer Scientific\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Schaefer-Scientific-logo.webp\",\"contentUrl\":\"https:\\\/\\\/schaefer-scientific.com\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/Schaefer-Scientific-logo.webp\",\"width\":1177,\"height\":97,\"caption\":\"Schaefer Scientific\"},\"image\":{\"@id\":\"https:\\\/\\\/schaefer-scientific.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Kapazit\u00e4tsbr\u00fccken - Schaefer Scientific","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/schaefer-scientific.com\/de\/produkt\/kapazitatsbrucken\/","og_locale":"de_DE","og_type":"article","og_title":"Capacitance bridges - Schaefer Scientific","og_description":"Precision capacitance measuring bridges The capacitance measuring bridges from the manufacturer Andeen-Hagerling offer a capacitance resolution down to the sub-attofarad (10-18&nbsp;F!) These measuring bridges have proven themselves for many years in a wide range of applications and are the basis for corresponding publications: General Specifications(Option-E: with improved accuracy) Multi-frequency Models AH 2700A(Option-E) AH 2700A Option-C(Option-E) [&hellip;]","og_url":"https:\/\/schaefer-scientific.com\/de\/produkt\/kapazitatsbrucken\/","og_site_name":"Schaefer Scientific","article_modified_time":"2026-02-09T07:49:53+00:00","og_image":[{"width":1321,"height":510,"url":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"2\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/schaefer-scientific.com\/product\/capacitance-bridges","url":"https:\/\/schaefer-scientific.com\/product\/capacitance-bridges","name":"Kapazit\u00e4tsbr\u00fccken - Schaefer Scientific","isPartOf":{"@id":"https:\/\/schaefer-scientific.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/schaefer-scientific.com\/product\/capacitance-bridges#primaryimage"},"image":{"@id":"https:\/\/schaefer-scientific.com\/product\/capacitance-bridges#primaryimage"},"thumbnailUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs.webp","datePublished":"2025-07-18T08:54:32+00:00","dateModified":"2026-02-09T07:49:53+00:00","breadcrumb":{"@id":"https:\/\/schaefer-scientific.com\/product\/capacitance-bridges#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/schaefer-scientific.com\/product\/capacitance-bridges"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/schaefer-scientific.com\/product\/capacitance-bridges#primaryimage","url":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs.webp","contentUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/07\/2700Aphoto-GOOD-LowREs.webp","width":1321,"height":510},{"@type":"BreadcrumbList","@id":"https:\/\/schaefer-scientific.com\/product\/capacitance-bridges#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/schaefer-scientific.com\/"},{"@type":"ListItem","position":2,"name":"Capacitance bridges"}]},{"@type":"WebSite","@id":"https:\/\/schaefer-scientific.com\/#website","url":"https:\/\/schaefer-scientific.com\/","name":"Schaefer Scientific","description":"","publisher":{"@id":"https:\/\/schaefer-scientific.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/schaefer-scientific.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/schaefer-scientific.com\/#organization","name":"Schaefer Scientific","url":"https:\/\/schaefer-scientific.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/schaefer-scientific.com\/#\/schema\/logo\/image\/","url":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/06\/Schaefer-Scientific-logo.webp","contentUrl":"https:\/\/schaefer-scientific.com\/wp-content\/uploads\/2025\/06\/Schaefer-Scientific-logo.webp","width":1177,"height":97,"caption":"Schaefer Scientific"},"image":{"@id":"https:\/\/schaefer-scientific.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/product\/1192","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/media\/1193"}],"wp:attachment":[{"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/media?parent=1192"}],"wp:term":[{"taxonomy":"application","embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/application?post=1192"},{"taxonomy":"manufacturer","embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/manufacturer?post=1192"},{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/schaefer-scientific.com\/de\/wp-json\/wp\/v2\/product-category?post=1192"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}